RAD-X HF Premier Vet System

RADXHF Premier Vet System

The RAD-X HF Premier Vet Systems are the flexible choice when selecting a new x-ray suite for your hospital.

We can tailor a package to suit your individual requirements and desires rather than an off the shelf system that you may not be an ideal solution for you. The table tubestand combination provides the ultimate in positioning possibilities with movement in all practical directions. This is the best European manufactured offering we could find and surpasses the quality of all other options in the market.
The RAD-X P Series High Frequency X-ray Generator choice is from 20 to 60 kilowatt with the most popular veterinary option being the 30kW PSE-30 Stored Energy with a matching x-ray tube with focal spots and performance to suit. Full Anatomical Programming is standard and in manual mode you have a choice of 2 or 3 point programming. This means you can select kV and mAs or have more control of the image using kV, mA and time. These generators carry a 5 year manufacturer's parts warranty. The RAD-X HF Premier Vet System is built to a performance, service and quality standard to keep you happy now and into the future.

RAD-X VTT - Integrated Table Tubestand - ultimate flexibility in a tight spot

4 Way Float Top Table – 1525 x 730mm – moves longitudinally and laterally with
electromagnetic locks – controlled by a foot pedal across the front of the table.
Fixed Fine Line Grid – 10:1 Ratio, 103lpi, 100cm focus. Option for moving bucky grid.
Medical grade stainless steel cassette tray fully adjustable to all cassette sizes
positioned either way in the tray. Grid cabinet interlocks automatically with tubestand.
Tubestand – travels the entire longitudinal length of the table base. The grid cabinet
disengages automatically when the tube stand is moved to the extreme end of the table.
Tube height is adjustable from 1200mm down to the table top at the press of a button.
Tube rotates through 180 degrees for angled exposures or standing lateral views if required.
Laser guide on the collimator indicates the centre of the grid cabinet for correct positioning
of angled exposures. Disengaged grid cabinet can be moved independently of the tubestand.

APR Console

Generator Options

RAD-X PSE-30TV Stored Energy 30kW High Frequency Generator

  • 125kV 40 – 125kV in 1 kV increments.
  • 400mA 25,50,75,100,150,200,250,300 and 400mA selections.
  • Time Selections 0.002 – 2 Seconds.
  • mAs selections up to 30mAs.

Factor selection choices:

  • 3 Point control – kV, mA and time.
  • 2 Point control – kV and mAs.
  • APR – Anatomical Programs – 12 Anatomical Regions, just select the region, select view, enter subject thickness in cm and expose. Fully adjustable to suit you film screen combination. Control Console mounting - options for wall or bench.

High frequency waveform gives shorter exposure times, lower subject dose and greater accuracy, exposure to exposure.
Microprocessor control provides increased consistency and efficient operation.
Extended x-ray tube life through advanced protection circuitry.
Automated line voltage compensation – no manual adjustments required.
Onboard self-diagnostics – advanced system protection, increased serviceability.
Power required for a 30kW Stored Energy generator is - 15 amps. The wall outlet should be the standard three-pin 15amp fitting.

RAD-X P400 37.5kW High Frequency Generator

  • 125kV 40 – 125kV in 1 kV increments.
  • 400mA 25,50,75,100,150,200,250,300 and 400mA selections.
  • Time Selections 0.002 – 6 Seconds.
  • mAs selections up to 600mAs.

Factor selection choices:

  • 3 Point control – kV, mA and time.
  • 2 Point control – kV and mAs.
  • APR – Anatomical Programs – 12 Anatomical Regions, just select the region, select view, enter subject thickness in cm and expose. Fully adjustable to suit you film/screen combination or digital acquisition. Control Console mounting - options for wall or bench.

High frequency waveform gives shorter exposure times, lower subject dose and
greater accuracy, exposure to exposure.
Microprocessor control provides increased consistency and efficient operation.
Extended x-ray tube life through advanced protection circuitry.
Automated line voltage compensation – no manual adjustments required.
Onboard self-diagnostics – advanced system protection, increased serviceability.
Power required for a 37.5kW generator is generally - 63 amps per phase on 3 phases – neutral and earth.

Generator

Generator Mounting Options

These generators are mounted in a cabinet in standard installations, providing ease of service and component protection.

Tube Options

  • X-ray Tube – Toshiba E7242X – 0.6 / 1.5mm Dual Focal Spot
  • X-ray Tube – Toshiba E7239X – 1.0 / 2.0mm Dual Focal Spot

Toshiba E7242X